Model | Metrix+ 171TRMS+ | |||
Safety standard | GB/T 13978-92, IEC 61010-1, IEC 61010-2-032, CAT III 1000V CAT IV 600V | |||
DC Voltage | Range | Resolution | Accuracy | |
600mV | 0.1mV | +(0.5% + 3) | ||
6V | 1mV | +(0.5% + 3) | ||
60V | 10mV | +(0.5% + 3) | ||
600V | 100mV | +(0.5% + 3) | ||
1000V | 1V | +(0.8% + 5) | ||
AC Voltage(True RMS) | Range | Resolution | Accuracy | |
6V | 1mV | +(0.8% + 3) | ||
60V | 10mV | +(0.8% + 3) | ||
600V | 100mV | +(1% + 10) | ||
750V | 1V | +(1% + 10) | ||
DC Current | Range | Resolution | Accuracy | |
60mA | 10uA | +(1% + 3) | ||
600mA | 100uA | +(1% + 3) | ||
20A | 10mA | +(1.5% + 3) | ||
AC Current (True RMS) | Range | Resolution | Accuracy | |
6uA | 10nA | +(0.8% + 3) | ||
60mA | 10uA | +(0.8% + 3) | ||
600mA | 100uA | +(0.8% + 3) | ||
20A | 10mA | +(1.2% + 3) | ||
Resistance | Range | Resolution | Accuracy | |
600 | 0.1 | +(0.8% + 3) | ||
6K | 1 | +(0.8% + 3) | ||
60K | 10 | +(0.8% + 3) | ||
600K | 100 | +(0.8% + 3) | ||
6M | 1K | +(1.2% + 3) | ||
60M | 10K | +(1.2% + 3) | ||
Capacitance | Range | Resolution | Accuracy | |
9.999nF | 1pF | +(4% + 3) | ||
99.99nF | 10pF | +(4% + 3) | ||
999.9nF | 100pF | +(4% + 3) | ||
9.999uF | 1nF | +(4% + 3) | ||
99.99uF | 10nF | +(4% + 3) | ||
999.9uF | 100nF | +(4% + 3) | ||
9.999mF | 1uF | +(5% + 3) | ||
99.99mF | 10uF | +(5% + 3) | ||
Temperature | Range | Resolution | Accuracy | |
-20 ~ 300C | 1C | +(1% + 4) | ||
301 ~ 1000C | 1C | +(1.9% + 5) | ||
-4F ~ 600F | 1F | +(1.2% + 6) | ||
601F ~ 1832F | 1F | +(1.9% + 6) | ||
Frequency | Range | Resolution | Accuracy | |
9.999Hz | 1mHz | +(1% + 3) | ||
99.99Hz | 10mHz | +(1% + 3) | ||
999.9Hz | 100mHz | +(1% + 3) | ||
9.999kHz | 1Hz | +(1% + 3) | ||
99.99kHz | 10Hz | +(1% + 3) | ||
999.9kHz | 10Hz | +(1% + 3) | ||
9.999MHz | 1kHz | +(1% + 3) | ||
Duty Ratio | Range | Resolution | Accuracy | |
0.1 99.9% | 0.10% | +3% | ||
hFe | Display reads hFe approximation(0 ~ 1000) ; Ibo ~ 10uA Vce ~ 2.8V | |||
Additional functionalities | Diode, continuity, backlight, flashlight, NCV, low battery indication, auto power off, data hold | |||
Sampling time | About 3 times/sec | |||
Display | 6000 counts backlit LCD | |||
Fuse | uA, mA Gear fuse FF630mA/250V; A Gear Fuse :FF20A/250V | |||
Operating temperature | 18C ~ 28C | |||
Storage temperature | -10C ~ 50C | |||
Power | 1 x 9V 6F22 | |||
Size & weight | 190 x 90 x 50 mm, approx. 380g(incl. battery) | |||
Standard Accessories | Main unit, test leads, temperature probe, user manual, battery |